- ÈÛµãÒÇ¡¢Îí¶ÈÒÇ¡¢µÎµãÒÇ
- ¼ÓÈȯ
- ¶¨µªÒÇ
- Ö²ÎïÉú³¤Ïä
- ºæÏä/Ãð¾úÆ÷
- »ùÒòÀ©Ôö(PCR)ÒÇ
- ˮԡ/Ò¡´²
- Âí¸¥Â¯
- ϸ¾ú¼ì²âÒÇ
- Ïû»¯Â¯
- Ö¬·¾²â¶¨ÒÇ
- ÝÍȡװÖÃ
- ³¬Éù²¨Ï¸°ûÆÆËé
- ¿âÂØÒÇ
- ÀäÈ´Æ÷
- ºãλìÔÈÆ÷
- Õñµ´»ìÔÈÆ÷
- ¸ßί
- µÎ¶¨¹Ü
- µç»¯Ñ§·ÖÎöÒÇ
- ʵÑéÀä¹ñ
- ÖÆ±ù»ú
- ÅàÑø¼Ü
- ÏËά²â¶¨ÒÇ
- ¸ÉÔïÒÇ
- ²â¹¯ÒÇ
- ³¬Éù²¨ÇåÏ´Æ÷
- ¹Ä·ç¸ÉÔïÏä¡¢ÀÏ»¯ÊÔÑéÏä¡¢Õæ¿Õ¸É
- ¾»»¯¹¤×÷̨
- ÓÍÔ¡¡¢ÓͲۡ¢Ë®Ô¡¹ø¡¢Ñ»·±Ã
- ·ÛËé»ú¡¢´¿Ë®»ú¡¢µçÈȰ塢ÐýתÕô
- ½Á°èÆ÷
- Õñµ´Æ÷
- ΢ÉúÎï¼ì²âÒÇ
- µç×ÓÌìÆ½
- µÎ¶¨ÒÇ
- Ó²¶ÈÒÇ/ÃܶȼÆ
- ¾ùÖÊÒÇ
- Õæ¿Õ±Ã
- ÀëÐÄ»ú
- BODÅàÑøÏä
- ºãÎÂË®²Û
- ¹ýÂËÉ豸
- ϸ¾úÅàÑøÏä
- Éú»¯ÅàÑøÏä
- ¿ª¿ÚÉÁµã×Ô¶¯²â¶¨ÒÇ
- ÒÆÒºÆ÷/ÆøÌå½øÑùÆ÷
- ºãκãʪÅàÑøÏä
ÓÊÏ䣺1202723@QQ.COM
QQ£º1202723
ÊÖ»ú΢Ðźţº18901191778
µØÖ·£º±±¾©Êг¯ÑôÇøÇåºÓÓª¶«Â·2ºÅÔº2ºÅÂ¥1111ÊÒ
MiniOpticon ˫ɫʵʱӫ¹â¶¨Á¿ PCR
MiniOpticon ˫ɫʵʱӫ¹â¶¨Á¿ PCR
MiniOpticon ˫ɫʵʱӫ¹â¶¨Á¿ PCR
¡¾½éÉÜ¡¿
MiniOpticonʵʱPCR¼ì²âϵͳÓɸßÐÔÄܵÄMJ minicyclerºÍ½ô´ÕµÄ˫ɫʵʱ¼ì²âÆ÷×é³É£»ÊÇ×îСµÄºÍ×î±ãЯµÄʵʱPCRϵͳ¡£
MiniOpticon Ó¦ÓÃÁËÔÚOpticon2ϵͳÉϹ㷺ʹÓõ路¢ºÍ¼ì²â¼¼Êõ£¬48¸ö¶ÀÁ¢µÄLED£¨·¢¹â¶þ¼«¹Ü£©ÕóÁÐ×÷Ϊ¼¤·¢¹âÔ´£¬Ë³Ðò¼ì²âÑùÆ·¡£Ã¿Ò»¸öLEDµÄ¹âÊø¶Ô×¼Ò»¸öÑùÆ·¿×£¬±£Ö¤×îСµÄÐźŽ»²æºÍ¹âµÄÉ¢Éä¡£LEDÿ´ÎµãÁÁÒ»¸ö£¨48¸öÑùÆ·£¬2ɫӫ¹â¼ì²â£¬¼ì²âÒ»´ÎÓÃʱ9Ã룩¡£Ë³Ðò¼ì²âÒ²ÄܼõÉÙÐźŽ»²æ¡£LED ¹âÔ´ÊÙÃü³¤£¬ÎÞÐèÌØ±ðµÄά»¤¡£±»¼¤·¢³öµÄ·¢É䲨³¤ÐźŽøÈë2¸ö´øÂË¹âÆ¬µÄ¹âÃô¶þ¼«¹Ü£¨photodiode£©½øÐмì²â¡£
Õû»úûÓÐÔÚ¹¤×÷ʱÔ˶¯µÄ²¿¼þ£¬±£Ö¤¶¨Á¿¼ì²âºÍÎÞÐèÄý½º·ÖÎöµÄ¿É¿¿ÐÔ¡£
Ö÷ÒªÌØµã
˫ͨµÀ¼ì²â
¼ì²â48¸öÑùÆ·
½öÖØ15lb£¬½ô´ÕµÄÍâ¹Û£¨18 x 32 x 33 cm W x D x H£©¿ÉÒÔ½«ÒÇÆ÷·ÅÖÃÔÚÈκεط½
´øÓÐÌݶȵÄÈÈÑ»·ÏµÍ³£¬Ìṩ8¸ö²»Í¬µÄζÈÌõ¼þ£¬¿ÉÒÔÔÚͬһ¸öʵÑéÄÚÓÅ»¯·´Ó¦Ìõ¼þ
´´ÐµÄ48¸öLEDÕóÁк͹âÃô¶þ¼«¹Ü£¬ÎÞÐèÒÆ¶¯µÄ²¿¼þ
ͬһ̨µçÄÔ¿ÉÒÔͬʱ¿ØÖƶà´ó4̨ÒÇÆ÷¡£
¡¾¼¼ÊõÖ¸±ê¡¿
Base thermal cycler |
MJ Mini Cycler |
Sample capacity |
48-well PCR plate 6 x 8-tube strips |
Sample volume |
10–100 µl (20 µl recommended) |
Weight |
6.8 kg |
Dimensions (W x D x H) |
18 x 32 x 33 cm (7 x 12.5 x 13") |
Fluorescence excitation range |
470–500 nm |
Fluorescence detection ranges |
Channel 1: 523–543 nm |
|
|
Gradient Specifications |
|
Gradient range |
35–99°C |
Gradient accuracy |
±0.2°C of target at end columns within 30 sec (NIST–traceable) |
Temperature uniformity |
±0.4°C, in column, well-to-well, within 10 sec of target attainment |
Gradient calculator accuracy |
±0.4°C of actual column temperature (NIST–traceable) |
Temperature differential range |
1–16°C |
|
|
Recommended Computer Specifications |
|
Operating system |
Windows XP Professional |
Processor speed |
1.5 GHz |
Storage capacity |
20 GB hard drive |
Display |
1,024 x 768 pixel minimum screen resolution, 256 colors |
Memory |
512 MB RAM |
Note: Specifications subject to change without notice |