电话:010-84459554,84459554

邮箱:1202723@QQ.COM
QQ:1202723
手机微信号:18901191778
地址:北京市朝阳区清河营东路2号院2号楼1111室

当前位置: 首页 > 代理厂家 > 国产

丙烯腈气体检测管191L Acrylonitrile

丙烯腈气体检测管191L Acrylonitrile CH2:CHCN,Measuring Range 0.1 to 0.2ppm 0.2 to 6.0 ppm 6.0 to 18.0 ppm Number of Pump Stroke 4 2 1 Correction Factor,丙烯腈气体检测管价格

丙烯腈气体检测管191L Acrylonitrile的详细介绍

丙烯腈气体检测管191L Acrylonitrile
Acrylonitrile                  No.191L

CH2:CHCN

丙烯腈气体检测管191L Acrylonitrile
Performance
 

MeasuringRange

0.1 to 0.2ppm

0.2 to 6.0 ppm

6.0 to 18.0ppm

Number of PumpStroke

4

2

1

CorrectionFactor

1/2

1

3

Sampling Time

3 minutes per pumpstroke

Detecting Limit

0.05 ppm (n=4)

Color Change

Yellow → Pink

Reaction Principle

Pretreatmenttube: CH2:CHCN + Cr6+ +H2SO4 →HCN
Detector tube : 2HCN +HgCl2 → 2HCl + Hg(CN)2
HCl + Base → Chloride

Coefficient ofVariation

10% (for 0.25 to 1ppm), 5% (for 1 to 6 ppm)

ShelfLife 3Years
Correctionsfor
temperature & humidity
Unnecessary
Store the tubes at cool and darkplace.

Possible coexisting substances and theirinterferences (NOTE)


Substance

Concentration

Interference

Change color by itself

Hydrogenchloride

-

No effect

Nodiscoloration

Hydrogencyanide

-

No effect

Nodiscoloration

Nitriles(丙烯腈气体检测管191L AcrylonitrileC3)

-

Plus error

Discolor pinkstain

Acetonecyanohidrin

-

Plus error

Discolor pinkstain

Alcohols, Esters,Ketones

-

No effect

Nodiscoloration

Aromatichydrocarbons

-

No effect

Nodiscoloration



Othersubstance measurable with this detector tube


Substance

CorrectionFactor

No. of PumpStrokes

MeasuringRange

n-Butyronitrile

30

1

6 to 180 ppm

2-Methyl-3-butenenitrile

2.0

2

0.4 to 12 ppm

2-Pentenenitrile

1.2

2

0.24 to 7.2ppm

3-Pentenenitrile

2.0

2

0.4 to 12ppm



Calibration gasgeneration Diffusion tubemethod



TLV-TWA TLV-STEL Explosive range
2ppm - 3 to17%